SAFETY GATEReference SR/01501/26

Lighting chain — descarga eléctrica

Descriptive title organised by NagameAlert; the official wording is available from the source.

Official information organised for easier consultation. The source publication remains authoritative.

Identification

Product identification

Product
Lighting chain
Category
Lighting chains
Lot/s
3856014582844
Product domain
Non-foodNagameAlert treatment

Official information

Risk and measures

Risk or hazard
Electric shock
Official description
The product lacks sufficient insulation. Furthermore, the product has insufficient nominal cross-section of the conductors. The creepage and clearance distance between the circuits is insufficient, the user could touch accessible live parts and receive an electric shock. Moreover, due to inadequate insulation, a short circuit could cause a fire. The product does not comply with the requirements of the Low Voltage Directive nor with the European standards EN 60598-1 and EN 60598-2-20.
Measures
Type of economic operator to whom the measure(s) were ordered: ImporterCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: 07/04/2026Type of economic operator to whom the measure(s) were ordered: ImporterCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 07/04/2026

Territory

Geography

Origin
People's Republic of China
Notifying country or territory
Croatia
Distribution
Notificado por Croatia