Skip to content
SAFETY GATEReference SR/00868/25

Surveillance, 4-Channel CCTV Surveillance Kit — descarga eléctrica

Descriptive title organised by NagameAlert; the official wording is available from the source.

Official information organised for easier consultation. The source publication remains authoritative.

Identification

Product identification

Product
Surveillance, 4-Channel CCTV Surveillance Kit
Brand
Levelone
Category
Electrical appliances and equipment
Lot/s
4015867227862
Product domain
Non-foodNagameAlert treatment

Official information

Risk and measures

Risk or hazard
Electric shock
Official description
The power supply cable is composed of a Class II plug (without a protective earth conductor) and a Class I connector. If the power supply cable is used with a Class I electric appliance, there is no continuation of the protective earth conductor. In the event of a fault, the fault current would not be able to flow via the protective earth conductor, leading to the risk of an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 60335-1.
Measures
Type of economic operator taking notified measure(s): ImporterCategory of measure(s): Replacement of the power cable in the goods in stock.Date of entry into force: 02/01/2025Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Recall of the power cable from end usersDate of entry into force: 02/01/2025

Territory

Geography

Origin
People's Republic of China
Notifying country or territory
Germany
Distribution
Notificado por Germany

Provenance and context

NagameAlert distinguishes content published by the source from its organisation and normalisation. Values marked “NagameAlert” belong to that processing layer. Always check measures, scope and updates in the official publication.