SAFETY GATEReference SR/00868/25
Surveillance, 4-Channel CCTV Surveillance Kit — descarga eléctrica
Descriptive title organised by NagameAlert; the official wording is available from the source.
Official information organised for easier consultation. The source publication remains authoritative.
Identification
Product identification
- Product
- Surveillance, 4-Channel CCTV Surveillance Kit
- Brand
- Levelone
- Category
- Electrical appliances and equipment
- Lot/s
- 4015867227862
- Product domain
- Non-foodNagameAlert treatment
Official information
Risk and measures
- Risk or hazard
- Electric shock
- Official description
- The power supply cable is composed of a Class II plug (without a protective earth conductor) and a Class I connector. If the power supply cable is used with a Class I electric appliance, there is no continuation of the protective earth conductor. In the event of a fault, the fault current would not be able to flow via the protective earth conductor, leading to the risk of an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 60335-1.
- Measures
- Type of economic operator taking notified measure(s): ImporterCategory of measure(s): Replacement of the power cable in the goods in stock.Date of entry into force: 02/01/2025Type of economic operator taking notified measure(s): DistributorCategory of measure(s): Recall of the power cable from end usersDate of entry into force: 02/01/2025
Territory
Geography
- Origin
- People's Republic of China
- Notifying country or territory
- Germany
- Distribution
- Notificado por Germany
Provenance and context