Injuries
Official description
The concrete screws for use as multiple fasteners in non-load-bearing redundant systems can spontaneously fail owing to hydrogen embrittlement. The weight they support is transferred to adjacent screws, which have the same potential defect and can also break. A zipper effect and thus a system failure must be expected. People can be injured by falling parts. The product does not comply with the Construction Products Regulation.
Measures
Type of economic operator to whom the measure(s) were ordered: ManufacturerCategory of measure(s): Withdrawal of the product from the marketDate of entry into force: 02/04/2024Type of economic operator to whom the measure(s) were ordered: ManufacturerCategory of measure(s): Warning consumers of the risksDate of entry into force: 02/04/2024Type of economic operator to whom the measure(s) were ordered: ManufacturerCategory of measure(s): Ban on the marketing of the product and any accompanying measuresDate of entry into force: 02/04/2024

Territory

Geography

Origin
Poland
Notifying country or territory
Germany
Distribution
Notificado por Germany

Provenance and context

NagameAlert distinguishes content published by the source from its organisation and normalisation. Values marked “NagameAlert” belong to that processing layer. Always check measures, scope and updates in the official publication.