OECDReference EN/KR/K21/EP/00054
LED lighting (Regular lighting)
Official information organised for easier consultation. The source publication remains authoritative.
Identification
Product identification
- Product
- LED lighting (Regular lighting)
- Category
- Light Bulbs/Tubes/Light-Emitting Diodes
- Model
- BT-CL-60WAC
- Product domain
- Non-foodNagameAlert treatment
Official information
Risk and measures
- Risk or hazard
- ㅇ Inadequate dielectric strength test result - Measured area: Live parts and enclosure and the areas between surfaces attached - Standard: It withstands AC 2,880 V (Class II appliance) - Measured value: It failed to withstand AC 2 880 V ㅇ Creepage distance not meeting the standard - Measured area: Area between live parts(LED module pattern), enclosure’s metal and the surface attached - Allowable level: 5.0 mm(Class II appliance) - Measured value: 1.19 mm * PCB back’s insulation parts removed ◇ Risk of electric shock in case of overvoltage ◇ Risk of electric shock if surface is touched
- Recommendations
- ◇ Consumers who have it must stop using the product immediately. ◇ Contact and visit the place of purchase for exchange, refund or repair, etc.
Official information
Economic operators
- Manufacturer
- -
Territory
Geography
- Origin
- Korea (Republic of)
- Distribution
- Retirada en Korea (Republic of)
- Country of recall
- Korea (Republic of)
Provenance and context