Skip to content
OECDReference EN/KR/K20/EP/00049

DC power supply

Official information organised for easier consultation. The source publication remains authoritative.

Identification

Product identification

Product
DC power supply
Category
Electrical Supplies
Model
SD1205B
Product domain
Non-foodNagameAlert treatment

Official information

Risk and measures

Risk or hazard
ㅇ (Primary defect) Temperature rise exceeding the standard (198 Vac, 60 Hz) -Transformer coil: Measured value: 117.2 ℃/Allowable level: 110 ℃ -Transformer core: Measured value: 116.2 ℃/Allowable level: 110 ℃(233.2 Vac, 60 Hz) -Transformer coil: Measured value: 114.9 ℃/Allowable level: 110 ℃ -Transformer core: Measured value: 115.2 ℃/Allowable level: 110 ℃ ㅇ Insufficient labelling – Type II appliance mark missing ◇ Risk of fire during normal use due to excessive temperature rise
Recommendations
◇ Consumers who have it must stop using the product immediately. ◇ Contact and visit the place of purchase for exchange, refund or repair, etc.

Official information

Economic operators

Manufacturer
-

Territory

Geography

Origin
Korea (Republic of)
Distribution
Retirada en Korea (Republic of)
Country of recall
Korea (Republic of)

Provenance and context

NagameAlert distinguishes content published by the source from its organisation and normalisation. Values marked “NagameAlert” belong to that processing layer. Always check measures, scope and updates in the official publication.