Product identification
- Product
- Ballast stabilizer & Lamp control system
- Category
- Electrical Supplies
- Model
- SO222024
- Product domain
- Non-foodNagameAlert treatment
Official information
Risk and measures
- Risk or hazard
- ㅇ Water resistance and insulation - Standard: Insulation resistance (IR) shall be at least 2 ㏁ or 4 ㏁ after being tested for water resistance. - Result: Insulation resistance between different poles turns out to be less than 2 ㏁. ㅇ Inadequate dielectric strength - Standard: It shall withstand the test voltage of AC 1 440 V or AC 3 630 V for one minute without breakdown. - Result: It failed to withstand the test voltage of AC 1 440 V for one minute between two different poles. ㅇ Insufficient labelling – Input current unlabelled - TC value unlabelled - Rated output current unlabelled - Maximum output voltage unlabelled ◇ Risk of electric shock in the event of overvoltage ◇ Risk of electric shock as the live parts are exposed outside ◇ Risk of providing wrong information
- Recommendations
- ◇ Consumers who have it must stop using the product immediately. ◇ Contact and visit the place of purchase for exchange, refund or repair, etc.
Official information
Economic operators
- Manufacturer
- -
Territory
Geography
- Origin
- Korea (Republic of)
- Distribution
- Retirada en Korea (Republic of)
- Country of recall
- Korea (Republic of)
Provenance and context